LibraryMAE-FM-01 · Rev. 1 · November 2026 Fluid mechanics
Statics, conservation laws, potential flow, pipe flow and boundary layers
Fluid statics and properties
| Quantity | Relation | Notes |
|---|
| Hydrostatic equation | dp/dz = −ρ g ; p = p₀ + ρ g h | h measured downwards |
| Buoyancy (Archimedes) | FB = ρfluid g V | |
| Newtonian viscosity | τ = μ du/dy ; ν = μ/ρ | air at 15 °C: μ ≈ 1.79 × 10⁻⁵ Pa s |
Conservation laws
| Quantity | Relation | Notes |
|---|
| Continuity | ∂ρ/∂t + ∇ · (ρV) = 0 ; ∇ · V = 0 (incompressible) | |
| Momentum, control volume | ΣF = ṁ (Vout − Vin) | steady, one inlet and one outlet |
| Navier–Stokes (incompressible) | ρ DV/Dt = −∇p + μ ∇²V + ρ g | |
| Bernoulli | p + ½ ρ V² + ρ g z = const | steady, inviscid, incompressible, along a streamline |
Potential flow
| Quantity | Relation | Notes |
|---|
| Velocity from potential and stream function | V = ∇φ ; u = ∂ψ/∂y , v = −∂ψ/∂x | irrotational, two-dimensional |
| Uniform flow | φ = V∞ x | |
| Source of strength Λ | φ = (Λ/2π) ln r | |
| Vortex of strength Γ | φ = −(Γ/2π) θ | clockwise positive Γ |
| Circular cylinder surface | Cp = 1 − 4 sin²θ | non-lifting case |
Pipe flow and boundary layers
| Quantity | Relation | Notes |
|---|
| Reynolds number | Re = ρ V L / μ | pipe flow laminar below about 2300 |
| Darcy–Weisbach | Δp = f (L/D) ½ ρ V² | laminar: f = 64/Re |
| Hagen–Poiseuille | Δp = 128 μ L Q / (π D⁴) | fully developed laminar flow |
| Laminar flat plate (Blasius) | δ/x ≈ 5.0/√Rex ; Cf = 1.328/√ReL | Cf: total skin-friction coefficient |
| Turbulent flat plate | δ/x ≈ 0.37/Rex1/5 ; Cf ≈ 0.074/ReL1/5 | empirical, moderate Reynolds numbers |
| Transition on a flat plate | Rex ≈ 5 × 10⁵ | depends strongly on disturbances |
| Other similarity parameters | Fr = V/√(gL) ; St = fL/V | Froude and Strouhal numbers |
Sources
- White, F. M., Fluid Mechanics, 8th ed., McGraw-Hill, 2016.
- Anderson, J. D., Fundamentals of Aerodynamics, 6th ed., McGraw-Hill, 2017.
- Schlichting, H. and Gersten, K., Boundary-Layer Theory, 9th ed., Springer, 2017.
Study material only. Not approved maintenance or operational data; always use the current approved documentation.