Control systems

LibraryMAE-CS-01 · Rev. 1 · November 2026

Control systems

Transfer functions, time response, stability, PID control and frequency response

Models

QuantityRelationNotes
Transfer functionG(s) = Y(s)/U(s)zero initial conditions
Negative feedback loopT(s) = G(s) / [1 + G(s)H(s)]
State spaceẋ = A x + B u ; y = C x + D u
From state space to transfer functionG(s) = C (sI − A)⁻¹ B + Dpoles = eigenvalues of A
Controllabilityrank [B AB … Aⁿ⁻¹B] = n

Time response

QuantityRelationNotes
First-order systemG = K/(τs + 1)63.2 % of final value at t = τ ; 2 % settling ≈ 4τ
Standard second-order systemG = ωₙ² / (s² + 2ζωₙ s + ωₙ²)
Percent overshootMp = exp(−πζ/√(1 − ζ²))
Peak timetp = π / (ωₙ√(1 − ζ²))
Settling time (2 %)ts ≈ 4/(ζωₙ)
Final value theoremy(∞) = lims→0 s Y(s)if the system is stable

Steady-state error and stability

QuantityRelationNotes
Position error constantKp = lims→0 G(s) ; ess = 1/(1 + Kp)unit step, unity feedback
Velocity error constantKv = lims→0 s G(s) ; ess = 1/Kvunit ramp
Stabilityall closed-loop poles in the left half-plane
Routh–Hurwitzsign changes in the first column = number of right-half-plane roots

Controllers and frequency response

QuantityRelationNotes
PID controllerC(s) = Kp + Ki/s + Kd s
Gain in decibels|G|dB = 20 log₁₀ |G(jω)|
First-order pole on a Bode plotcorner at ω = 1/τ, then −20 dB per decadephase −45° at the corner
Gain margin1/|G(jω180)|ω180: phase crossover
Phase margin180° + ∠G(jωc)ωc: gain crossover, |G| = 1

Sources

  1. Ogata, K., Modern Control Engineering, 5th ed., Pearson, 2010.
  2. Nise, N. S., Control Systems Engineering, 7th ed., Wiley, 2015.
  3. Franklin, G. F., Powell, J. D. and Emami-Naeini, A., Feedback Control of Dynamic Systems, 8th ed., Pearson, 2019.

Study material only. Not approved maintenance or operational data; always use the current approved documentation.

Mr Aircraft Engineer — open aviation and aerospace education.Study material only; not approved maintenance data.About · Contact · Privacy · Terms