LibraryMAE-PH-01 · Rev. 1 · November 2026 Engineering mechanics and dynamics
Statics, particle and rigid-body dynamics, rotation and vibration
Statics
| Quantity | Relation | Notes |
|---|
| Equilibrium | ΣF = 0 ; ΣM = 0 | in each direction and about any point |
| Moment of a force | M = r × F ; |M| = F d | d: perpendicular distance |
| Dry friction | F ≤ μs N ; F = μk N when sliding | |
| Centroid | x̄ = Σ xiAi / ΣAi | centre of gravity with weights |
Kinematics and kinetics of a particle
| Quantity | Relation | Notes |
|---|
| Constant acceleration | v = u + a t ; s = u t + ½ a t² ; v² = u² + 2 a s | |
| Newton’s second law | F = m a = dp/dt | p = m v |
| Impulse–momentum | ∫F dt = Δp | |
| Work and energy | W = ∫F · ds ; KE = ½ m v² ; PE = m g h | |
| Power | P = F · v | |
| Circular motion | v = ω r ; an = v²/r = ω² r | centripetal acceleration |
Rigid-body rotation
| Quantity | Relation | Notes |
|---|
| Equation of motion | τ = I α | about a fixed axis or the centre of mass |
| Rotational speed | ω = 2π N / 60 | N in rev/min, ω in rad/s |
| Rotational energy and power | KE = ½ I ω² ; P = τ ω | |
| Angular momentum | H = I ω | |
| Gyroscopic precession | Ωp = τ / (I ω) | rotor spin ω, applied torque τ |
| Parallel-axis theorem | I = IG + m d² | |
| Slender rod, length L | I = mL²/12 (centre) ; mL²/3 (end) | |
| Solid cylinder / thin ring | I = ½ m r² ; I = m r² | about the axis of symmetry |
| Solid sphere | I = ⅖ m r² | |
Vibration
| Quantity | Relation | Notes |
|---|
| Undamped natural frequency | ωₙ = √(k/m) ; fₙ = ωₙ / 2π | |
| Simple pendulum | T = 2π √(L/g) | small amplitudes |
| Logarithmic decrement | δ = ln(x₁/x₂) ≈ 2πζ | light damping, successive peaks |
| Forced response at resonance | X/Xstatic = 1/(2ζ) | excitation at ωₙ |
Sources
- Hibbeler, R. C., Engineering Mechanics: Statics and Dynamics, 14th ed., Pearson, 2016.
- Ling, S. J., Sanny, J. and Moebs, W., University Physics, Volume 1, OpenStax, Rice University, 2016.
- Rao, S. S., Mechanical Vibrations, 6th ed., Pearson, 2017.
Study material only. Not approved maintenance or operational data; always use the current approved documentation.